Viscosity
Bath
Kinematic viscosity is of primary importance in the design and selection of a wide range of petroleum products. Calibrated capillary visco meters are used…
Low Temperature Viscosity Bath
Double walled construction with inner cylindrical Dewar flask and outer metal casing with toughened glass window provided on the front side…
Redwood
Viscometer
As per IP 70 For determination of viscosity of lubricating oils and fuels with stainless steel jet. Suitable for viscosity below 2000 secs.
GENERAL TEST EQUIPMENT
Magnetic Quencho
Meter
Comprising of electronically controlled Furnace with digital temperature controller. High grade alloy metal round ball. Thick Gauge stainless steel vessel with magnets.
Aniline Point
Apparatus
Consists of U-tube; 400mL borosilicate glass beaker; cover assembly with bath stirrer; sample stirrer and cooling coil; 6V lamp with line cord; and drive motor…..
Density Bath
Density Bath for two cylinders with Refrigeration, heating and control system.
FUELS
Existent Gum
Bath
Comprising of solid block bath for five test beakers. Fully automatic digital temperature controller. The design of the block and the manifold will be ensured…
Reid Vapour
Pressure Bath
Bath for double test with Micro-PID digital temperature controller. The bath depth will be such that, the vapour pressure bomb is immersed to at least 25mm above the top of air chamber.
Copper Corrosion
Bath
The copper strip tarnish test assesses the relative degree of corrosivity of petroleum products, including aviation fuels, automotive gasoline, natural gasoline…
Cold Filter
Plugging Point
Determines the low temperature flow characteristics of automotive diesel fuels and gas oils, including samples with flow improving additives…
Oil Centrifuge
With Heating
Centrifugation provides a convenient means of determining sediment and water content in crude oil, fuel oils and middle distillate fuels. Also used in…
Oil Centrifuge
(Amount of water and sediments )
As per ASTM D-893, the floor model includes a remote, speed meter, digital timer, safety interlocks, and castor wheels for mobility.
Ramsbottom Carbon Residue
Comprising of Coking furnace with 5 bulb wells,
(4 each for cking bulbs and 1 for the control bulb). Temperature is accurately controlled and maintained by fully…
Distillation
Apparatus
IP123 with electric heating assembly with Copper coil type voltage variac temperature controller, cooling bath (non-refrigeration),distillation flask 125ml…
Micro
Carbon
This test method covers the determination of the amount of carbon residue formed after evaporation and pyrolysis of petroleum materials under certain conditions and is intended…
Total Sediment
Analyser
Consists of 1 liter single neck round bottom flask, Dean & stark receiver, water cooled glass condenser and 5ml water trap…
Oxidation Stability Oil Bath
The method assesses the tendency of lubricants to deteriorate by oxidation under specified conditions of artificial ageing.
Oxidation
Characteristic
ASTM D-943 For Inhibited Mineral Oils – This test method covers the evaluation of the oxidation stability of inhibited…
Silver Corrosion Bath
As per IP-227 & ASTM D-4636
Made up of 304 AISI stainless steel for 4 samples. Amber coloured test tube & Cold Finger Condenser made of heat resistant borosilicate glass with hook & cradle…
LUBRICATING OIL
Foam
Bath
Foaming of lubricating oils in applications involving turbulence, high speed gearing or high volume pumping can cause inadequate lubrication, cavitation..
Demulsibilty
Bath
The ability of a lubricating oil to separate from water and resist emulsification is an important performance characteristic for applications involving water contamination and turbulence.
Oxidation Stability Dry Bath
Oxidation stability is determined by exposing the sample to a measured oxygen flow at elevated temperature in the presence of metal catalysts. Complete with solid aluminum…
Oxidation Stablity By Rotating Bomb Method
Comprising of solid block bath for five test beakers. Fully automatic digital temperature controller. The design of the block and the manifold will be ensured…
Rusting
Bath
Bath for double test with Micro-PID digital temperature controller. The bath depth will be such that, the vapour pressure bomb is immersed to at least 25mm above the top of air chamber.
Cloud and Pour
Point Tester
The copper strip tarnish test assesses the relative degree of corrosivity of petroleum products, including aviation fuels, automotive gasoline, natural gasoline…
Flock Point of Refrigerating Oils
Flock point is the temperature at which precipitation in the form of cloudiness or flakes can be observed with a 10:90 mixture of oil and refrigerant.
Chemical Stability By Sealed Glass Tube Method
The sealed tube containing refrigerant, lubricant and metal components is used at an elevated temperature. The content of the tube are evaluated by quantitative or qualitative…
Channel
Point
To determine channel point of gear oil at various low temperatures. Low temperature bath with digital controller.
Noack Evaporation
Loss
This method covers the determination of evaporation loss of lubricating oils. An oil sample is heated to 2500C…
Colour
Comparator
Colour comparator box with two number colour disc & artificial day light as per above test method. Box made of epoxy powder coated.
Dean & Stark
Appartus
Consists of 1 liter single neck round bottom flask, Dean & stark receiver, water cooled glass condenser and 5ml water trap…
Humidity Cabinet Rust Prevent Oils
This test method covers the evaluation of the Rust Preventive Properties of metal Preservatives under condition of high humidity Rectangular digitally controlled Constant temperature water bath.
Air Release Value Determination
Impinger method.Electronic digital temperature control.Pressure gauge with needle valve.Fixtures for test vessel.Pre-heating oven of 20 litre capacity.Circulation bath with external circulation device.
Hydrolytic Stability of Hydraulic Fluids
This test method covers the determination of the hydrolytic stability of hydraulic oils and turbine oils.
Sulphur Determination Equipment
The equipment consist of Tube Furnace, Microprocessor Based Digital Temperature Controller. Inlet & Outlet silicon tubing with pressure reducing conical flask.
CNOMO Test
(Antifoam)
Application: To find tendency of a emulsion / solution to foam in oil Industries. Antifoam CNOMO Recirculation Test Apparatus-3 Station Unit.
Oxidation Stability Dry Bath IP48
Super engineered and designed having required holes (12) well machined to accept oxidation and absorption tubes, leaving very little air space around the test cylinders.
FLASH POINT
Penksky Marten Flashpoint Tester
Dual speed – Deluxe model With oil cup, lid, gas ignition device. Electric driven stirring device with dual speed 90-120 rpm and 250 rpm.
ABEL Closed Cup Flash Point Apparatus
Includes water bath with electrically heated model energy regulator control, Funnel, test insert with lid and shutter, oil test jet facility.
Cleveland Open Cup Flash Point Tester
Open cup. Heating air bath with temperature controller and gas regulator. Test assembly with oil cup, gas ignition device & lifting handle..