B.O.D. COOLING INCUBATORS
BOD test chambers are especially built to pass FDA and ICH compliance standards and have a reputation for reliability, quality and performance.
- Construction as per cGMP regulations.
- Consisting of refrigeration, air handling, humidification, dehumidification, temperature/humidity controlling
- Microprocessor based PID Temperature controller OR
PLC based system for chamber control and auto changeover of standby system with touch screen display. - Printer interface & PC interface for data storage
- Standard networking via Ethernet.
Data Acquisition system complying to US FDA 21 CFR Part 11
- Data records & process control systems have Electronic Signature & Electronic Record capability. The controllers have a lockout feature that permits changes through a 21CFR Part11 compliant operator station, thus providing the necessary audit trail.
- Mean Kinetic Temperature value.
- Password security for log in and door operations.
- Operators need to enter user name and password before taking any action.
- Report search option using date and sample name.
- Secure computer generated, time stamped runtime audit trail of batch stop/start, alarm acknowledgements, logins, signature details, configuration changes.
- User actions with signing and authorization.
- Access control according to authority level.
- Export conversion facility to Excel.
Temperature Data Logger :
4 channel or 8 channel , calibrated data logger to print date, time, temperature set and process values for mapping and auto validation. Features like printer and PC interfacing provided.
Standby Systems :
Standby refrigeration and sensor.
Mobile Alert :
- Different Alarm indication through Mobile SMS Alert (from single to multi user)
- Process value indication through Mobile SMS Alert(from single to multi user)
Validation :
DQ/ FAT /IQ / OQ / PQ documentation with test and calibration certificate.
Safety features :
- Audio alarm provided to signal variation in temperature.
- Safety digital temperature controller for main controller : In the event of failure of Micro-PID Controller the high accurate safety controller will take over temperature controlling.
- In built over load protector provided for hermetic sealed compressor.
Temperature Range | : 5°C to 60°C |
Accuracy | : ± 0.2°C |
Temperature uniformity | : ± 1°C. |
Power supply | : 1 Phase, 230V ± 10% AC, 50 Hz |
Internal & External dimension :
Models | Capacity Litres |
Internal chamber dimension W x D x H (mm) |
External dimension W x D x H (mm) |
Weight (Kg) | Trays |
---|---|---|---|---|---|
WIL-165A | 90 | 450 x 450 x 450 | 710 x 925 x 1070 | 115 | 2 |
WIL-165B | 200 | 600 x 450 x 750 | 800 x 925 x 1370 | 165 | 3 |
WIL-165C | 400 | 600 x 600 x 1100 | 800 x 1090 x 1720 | 235 | 4 |
WIL-165D | 800 | 800 x 750 x 1300 | 1000 x 1250 x 1930 | 300 | 8 |
WIL-165E | 1000 | 800 x 800 x 1520 | 1000 x 1310 x 2150 | 340 | 10 |